Burnham C Series Brochure

Page of 4
effiCienCieS
 
and 
featureS
3
Pa
g
e
C Series Anticipated Efficiencies
natural Gas
#2 oIl
25% 
 
               50% 
 
             75% 
 
         100%
25% 
 
               50% 
 
             75% 
 
         100%
boiler HP
20
30
40
50
60
70
80
90
100
125
150
175
200
boiler HP
20
30
40
50
60
70
80
90
100
125
150
175
200
10 psig
83.2
83.7
83.9
84.1
84.3
84.4
84.4
84.6
84.7
84.3
84.7
84.9
85.1
10 psig
86.0
86.7
86.8
87.2
87.4
87.5
87.5
87.8
88.0
87.2
87.8
88.0
88.3
10 psig
83.5
83.8
83.9
84.1
84.3
84.3
84.3
84.6
84.8
84.1
84.6
84.8
85.0
10 psig
86.2
86.7
86.8
87.1
87.4
87.3
87.4
87.8
88.0
87.0
87.6
87.9
88.2
10 psig
83.2
83.4
83.4
83.7
84.0
83.9
83.9
84.3
84.6
83.4
84.1
84.3
84.6
10 psig
86.0
86.4
86.4
86.8
87.1
87.1
87.1
87.6
87.9
86.4
87.2
87.4
87.8
10 psig
82.6
82.7
82.7
83.0
83.4
83.3
83.3
83.8
84.2
82.6
83.5
83.7
84.1
10 psig
85.4
85.8
85.9
86.3
86.7
86.6
86.7
87.2
87.6
85.9
86.7
87.0
87.4
180°F Water
85.3
85.7
85.8
86.0
86.1
86.1
86.2
86.3
86.4
86.2
86.5
86.7
86.8
180°F Water
88.2
88.6
88.7
89.0
89.2
89.2
89.3
89.5
89.7
89.1
89.6
89.8
89.9
180°F Water
85.3
85.4
85.5
85.7
85.9
85.8
85.9
86.1
86.3
85.7
86.1
86.3
86.6
180°F Water
87.9
88.3
88.3
88.6
88.9
88.9
88.9
89.3
89.6
88.6
89.2
89.4
89.7
180°F Water
84.8
84.9
84.9
85.1
85.4
85.3
85.4
85.7
86.0
84.9
85.5
85.7
86.0
180°F Water
87.5
87.8
87.9
88.2
88.6
88.5
88.5
89.0
89.3
87.9
88.7
88.9
89.2
180°F Water
84.1
84.1
84.1
84.4
84.8
84.7
84.7
85.2
85.6
84.1
84.9
85.1
85.5
180°F Water
86.9
87.2
87.3
87.7
88.1
88.0
88.0
88.6
89.0
87.3
88.2
88.4
88.8
Standard Features*
3-Pass firetube construction
asme section iv construction
Water-cooled side walls
rolled and flared tube ends
Front and rear flue doors
oversized combustion chamber
Washout openings
top/vertical smokebox discharge
lifting lugs
enameled steel jacket
Fiberglass insulation
structural steel base with extended skid  
to protect burner during shipment
Optional Equipment*
locking quadrant damper
Combustion relief door
read/Horizontal smokebox discharge  
in lieu of top
stack thermometer
bolt-on front smokebox
Flue brush with handle
beaded tubes
Drain valve
Fork-lift base
Pre-piped and wired gas train
oversized gauges
steam & water trim connections
Steam
Gauge glass set
steam pressure gauge
operating control
manual-reset high limit
Firing rate control
low fire hold aquastat (when required)
manual-reset probe-type low water cut-off
Pump control/low water cut-off
Water
manual-reset low water cut-off
Pressure/temperature gauge
operating control
manual-reset high limit
Firing rate control
low fire hold aquastat (when required)
* burnham Commercial offers a wide array of optional equipment on the boiler and the burner.  