Bosch HES7052U Quick Setup Guide

Page of 48
English 11
14. Properly secure flexible conduit at knockout on angle and at supply side junc-
tion box. The wiring is now complete. 
Note: DO NOT plug in range at this time.
5D) Three Wire Flexible Conduit Con-
nection
The Four Wire Connection is preferred, but where local codes and ordinances 
permit grounding through neutral and/or conversion to four wire is impractical, unit 
may be connected to the power supply via a three wire connection.
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the terminal block.
3. Remove the top nut, star washer, and round washer from each post.
Note: DO NOT remove last round washer, last nut or internal wire leads.
4. Place one terminal lug (packaged with this manual) on each post. Replace the 
star washer and round washer and secure with 20 inch pounds of torque.
5. Strip 3/8 (9.53 mm) inches of insulation from the end of each wire.
 Figure 14: 
Completed Four Wire Flexible Conduit Connection
red wire
white wire
green 
ground 
screw
black wire
green ground wire
 Figure 15: 
Terminal Block
 Figure 16: 
Wire Stripping
3/8 “