Logitek Standard Elec. Cable Manufacturing C/A210 User Manual

Page of 18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
B
riCk
 i
nstallation
P
erformer
™ C/a210 B
riCk
 i
nstallation
CAUTION: Wear gloves during brick installation in case 
of sharp edges behind the stove. 
Note:  
Installation of the baffle bricks and insulating blanket 
is easier when you can still access the flue outlet, (before 
connecting the flue pipe). Be sure the insulating blanket 
is placed flat on the bricks so as not to block the flue. Use 
a ruler or a piece of kindling to reach over the blanket to be 
sure it is completely flat on top of the baffle bricks.
Measure bricks before installing, as per list of dimensions 
on next page, to be sure the correct bricks are installed in 
the correct location.
1.   Install bricks #1-26 in the numbered sequence shown 
in Figure 1.
      Important:  The secondary burn tubes at the top of the 
firebox are supported by a metal bracket. Move this 
bracket so it is centered left and right on the tubes. 
Also make sure the small supporting brackets on the 
front and rear tubes are centered and hanging from 
the steel rods at the front and rear of the stove.
2.   Next install bricks #27-38 on top of the stainless steel 
secondary burn tubes (Figures 2 & 3) in the upper part 
of the firebox. Bricks #27-32 fit up against the back wall 
of the firebox and rest on top of bricks #24-26 and the 
rear tube.  The steel support hanger should be centered 
between the sets of baffle bricks as shown in Figures 5 
and 6.
3.   Included with the stove are two 15-1/4”x 12”x 1/2” thick 
insulating blankets. Install one blanket above the baffle 
brick and to each side of the support bracket.
4.   Next, install the front baffle bricks #33-38 under the 
blanket and on top of the front two secondary tubes. 
Make sure that the blankets are centered side to side, 
rest flat on the baffle bricks, and do not project forward 
beyond the front of the baffle bricks #33-38.
WARNING:  IF THE BRICKS ARE NOT INSTALLED EXACTLY 
AS SHOWN BELOW, THEY COULD FALL OUT OF PLACE 
DURING REFUELING OR BURNING OF THE STOVE CAUS-
ING SERIOUS INJURY!
Performer™ C/A210 Brick Sizes 
(see Figures on this page)
A = 2-1/4 x 9” 
G = 1-1/2 x 9”
B = 4-1/2 x 5-1/2” 
H = 1-1/2 x 3” 
C = 4-1/2 x 6-1/4” 
K = 1-1/2 x 5-1/2”
D = 3 x 6-1/4” 
M = 2-1/8 x 6-1/4”
E = 3 x 9” 
S = 2-1/8”
F = 4-1/2 x 9”
Two insulating blankets each mearusing 1/2” x 12-1/2” 
x 15-1/4”.  They fit on top of the baffle brick (one on the 
left of the secondary tube support brackets and one on 
the right.
Front View
See the following for brick sizes
*Fits against the back of the firebox.
Note: These bricks may be slightly smaller to adjust for steel and fire-
brick tolerances beyond our control.  Be sure to measure and mark 
bricks with their numbers when removing.
Figure 1
Figure 2
Figure 3
Secondary Tube Supporting Brackets
Top View of Baffle Brick as Viewed from the Front
Secondary Tube Supporting Brackets
33
A
28
D
38
A
27
M
34
E
30
C
31
D
32
N
36
F
37
E
35
F
29
C
Side View of the Firebox
24
E
25
H
26
E
5
F
4
F
2
F
1
F
3
G
14
F
15
F
17
F
18
F
16
G
23
B
22
B
20
B
19
B
10
F 11
F
12
F
13
S
6
F
7
F
8
F
9
S
21
K
Firebox Brick Lay-Out Viewed From the Front