Summit PRO24G User Manual

Page of 37
 
2. Remove the knob from the gas tap. 
3. Use an appropriately sized 
screwdriver to adjust the flow rate 
adjustment screw. 
For LPG (butane – propane), turn the 
screw clockwise. 
For natural gas, turn the screw counter-
clockwise once. 
NOTE: The normal height of a straight 
flame in the reduced position is about 
1/4 inch.  
4. If the flame is higher than the desired 
position, turn the screw clockwise.  If 
it is smaller, turn counter-clockwise. 
5. For the last control, bring the burner 
both to high-flame and reduced 
positions and check whether the 
flame is on or off. 
Depending on the type of gas tap used 
in your appliance, the adjustment screw 
position may vary. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Exchange injector for the broiler 
1. Open broiler door. 
2. Unscrew fastening screw of the 
burner. 
3. Slightly pull the broiler burner (1) to 
lift it free with its link(s) on the rear 
side connected. 
4. Unscrew injector by turning in 
counter-clockwise direction (3). 
5. Fit new injector. 
 
 
 
 
 
 
 
1  Broiler burner 
2  Injector holder 
3  Injector 
 
Exchange injector for the oven 
1. Unscrew fastening screws on the 
back wall. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
18