BlueStar BSPROLINE Installation Instruction

Page of 47
PYRAMID STYLE DUCT INFORMATION 
MODEL 
BLOWER (cfm) 
DUCT SIZE 
BS-PC30240 
BS-PCIB600  
6” 
BS-PC36240 
BS-PCIB600  
6” 
BS-PC36240 
BS-PCIB1200  
10” 
BS-PC42240 
BS-PCIB600  
6” 
BS-PC42240 
BS-PCIB1200  
10” 
BS-PC48240 
BS-PCIB1200  
10” 
BS-PC54240 
BS-PCIB1200  
10” 
BS-PC60240 
BS-PCIB1200  
10” 
BS-PC66240 
BS-PCIB1200 
 
10” 
 
IMPORTANT PLANNING INFORMATION 
PROPER INSTALLATION OF DUCTING IS EXTREMELY INPORTANT FOR OPTIMAL PERFORMANCE OF 
YOUR BLUESTAR VENTILLATION SYSTEM.   
 ALL  CFM’S ARE BASED ON TESTS AT 0.1 STATIC PRESSURE; WITHOUT STATICE PRESSURE, ALL 
CFM’S WOULD BE OVERSATED.   
 STRAIGHT RUNS OR GRADUAL TURNS ARE BEST  
 NEVER USE FLEXIBLE DUCT WORK 
 PROPER PERFORMANCE IS DEPENDENT ON PROPER DUCT INSTALLATION, USE A QUALIFIED 
AND TRAINED INSTALLER 
 CONSULT WITH LOCAL CODES FOR MAKE UP AIR REQUIREMENTS 
BS-PCIB600 IS SIZED FOR A 6” DUCT.  TRC8/6 TRANSITION IS AVAILABLE TO INCREASE THE DUCT 
SIZE  TO 8” FOR OPTIMAL PERFORMANCE 
P/N 750306  Page   20