Summit GC2BGL Instruction Manual

Page of 16
 
9
CONVERSIONS 
Replacing Nozzles 
The burners can be adapted to suit different  
types of gas by fitting the nozzles that corres- 
pond to the gas used.  To do this, it is  
necessary to remove the burner heads and  
use a straight key "B", to unscrew the nozzle  
"A" (see Fig. 7) and replace it with a nozzle  
corresponding to the gas used. 
Be sure the nozzle is seated tightly. 
After making these replacements, the technician must regulate the burners 
as described in Adjustments
 on the previous page and apply the label 
corresponding to the new gas type in place of that previously applied.  This 
label is contained in the spare nozzle bag. 
For ease of the fitter, we have prepared a table indicating the flow capacities, the 
heat capacities of the burners, the diameter of the nozzles and the working 
pressure for the various types of gas. 
 
 
 
 
 
 
 
Burners 
Gas 
Normal 
Pressure, 
inches water 
column 
Injector 
Diameter, 
1/100 mm 
Nominal Heat 
Input (Btu/h) 
No. 
Description 
Min. 
Max. 
Rapid 
Propane HD-5 
Natural Gas 
11 
83 
145 
2400 
2400 
8350 
8350 
Semirapid 
Propane HD-5 
Natural Gas 
11 
58 
100 
2050 
1700 
4350 
4350 
Semirapid 
Propane HD-5 
Natural Gas 
11 
58 
100 
2050 
1700 
4350 
4350 
Auxiliary 
Propane HD-5 
Natural Gas 
11 
50 
90 
1200 
1400 
3400 
3400 
Arrangement  
of Burners 
Fig. 7