Summit GC2BGL Instruction Manual

Page of 16
 
8
ADJUSTMENTS 
Always disconnect the appliance from the electrical power source before 
making any adjustments.  All seals must be replaced by the technician 
when any adjustments are completed.
 
Taps 
"Reduced rate" adjustment: 
1. Switch on the burner and turn the corresponding knob to the "Reduced rate" 
position (small flame icon, Fig. 8, page 10). 
2. Remove knob "M" (Fig. 6), which is simply pressed onto its support rod. 
3. Insert a small screwdriver "D" into hole "C" (Fig. 6) and turn the throttle screw 
to the right or left until the burner flame has been adequately regulated to the 
"Reduced rate" position. 
Check that the flame does not go out when the knob is sharply switched from the 
"Full on" to the "Reduced rate" position. 
It is understood that only burners operating with Natural Gas or City Gas 
should be subjected to the above-mentioned adjustments.  The screw must 
be fully locked when the burners operate with Propane (turn clockwise). 
The operations described above can be carried out easily, whatever the position 
of the cooktop or however it is fastened to the work surface. 
THE BURNERS DO NOT REQUIRE ANY REGULATION OF INCOMING AIR. 
 
 
 
 
 
Fig. 6