8
                                                       INSTALLATION
CAUTION:  
During installation, persons installing the hood must wear heavy gloves 
to protect against sharp edges.
POSITIONING THE RANGE HOOD
Upon  completion  of  installation,  the  distance  between  the  hood  and    an  electric 
rangetop must be a minimum of 25" (65cm), and the distance between the hood and a 
gas rangetop must be a minimum of 30" (75cm).
min. 30" for gas ranges  
min. 25" for electric ranges  
PREPARING THE SITE
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY, 
OBSERVE THE FOLLOWING:
a.
Installation  work  and  electrical  wiring  must  be  done  by  quali?ed  personnel  in 
accordance  with  all  applicable  codes  and  standards,  including  ?re-rated 
construction.
b.
Sufficient air is needed for proper combustion and exhausting of gases through 
the ?ue (chimney) of fuel-burning equipment to prevent backdrafting.  Follow the 
range manufacturer's guidelines and safety standards such as those published by 
the  National  Fire  Protection  Association  (NFPA),  the  American  Society  for 
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local 
code authorities.
c.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and 
other hidden utilities.
d.
Ducted fans must always be vented to the outdoors.
 
 
 
 
 
 
 
 
 
 
  
Check Electric connection.  
(Supply voltage should be 1
10-120 V
, hood
should be connected to grounded socket.) 
Check lamp switch. 
(Lamp switch should be in on position.)
Hood does not operate 
Illumination lamp 
does not illuminate 
Air suction of 
hood is weak 
It does not exhaust 
air(in the ambient 
without chimney) 
Check motor switch. 
(Motor switch should be in I,II,III position) 
Check aluminum filter
(Aluminum cassette filter should be washed once a month 
under normal conditions.) 
Check bulbs. 
(Bulbs should be in good conditions.) 
Check air outlet chimney
(Air outlet chimney should be open.) 
Check carbon filter
(If it operates with carbon filter
, carbon filter should be
 replaced quarterly
.) 
X
X
X
X
X
X
X
X
X
X
TROUBLESHOOTING
If hood does not operate, before contacting customer service:
Be sure that the power cable is connected to the power supply and that the electric 
fuse for the installation is in good condition.   Before contacting the service, check 
your hood according to the table below.  If the problem continues, contact your dealer 
or  authorized service center.
Troubleshooting Guide
Service and Spare Parts 
You can obtain service advice and spare parts for your product directly from 
SUMMIT by calling us at 1-800-932-4267 or by going to our website at        
                                       www.summitappliance.com/support 
Have the model number of your range hood handy.  This can be found on the 
product label, which can be seen when you remove the aluminum cassette filter.   
An exploded view, parts list and wiring diagram for your unit can be found on the 
following pages of this manual.