DRYER VENTING REQUIREMENTS
Exhaust hood must be at least 12" (305 mm) from the ground 
or any object that may be in the path of the exhaust (such as 
flowers, rocks, bushes, or snow).
Maximum Vent Length/Vent Connection
Maximum length of vent system depends upon the type of vent 
used, number of elbows, and type of exhaust hood.
    
Vent System Chart (Rigid Metal Vent) 
                    
         No. of  
       Box and 
          Angled 
     90˚ Turns 
Louvered Hood              Hood                            
    
64 ft. (19.5 m) 
    58 ft. (17.7 m)
    
54 ft. (16.5 m) 
    48 ft. (14.6 m)
    
44 ft. (13.4 m) 
    38 ft. (11.6 m)
    
35 ft. (10.7 m) 
    29 ft. (8.8 m)
    
27 ft. (8.2 m) 
    21 ft. (6.4 m)
For vent systems not covered by the vent specification chart, 
see your parts distributor.
Provision must be made for enough air for combustion and 
ventilation. (Check governing codes and ordinances.) See 
“Recessed Area and Closet Installation Instructions” in the  
“Location Requirements” sections.
A 4" (102 mm) outlet hood is preferred. However, a 2
1
2
"  
(64 mm) outlet exhaust hood may be used. A 2
1
2
" (64 mm) 
outlet creates greater back pressure than other hood types.  
For permanent installation, a stationary vent system is required.
Connect Vent
1. 
 If connecting to existing vent, make sure the vent is clean. 
2.  Using a 4" (102 mm) clamp, connect vent to exhaust outlet 
in dryer. 
NOTE: Do not remove vent collar.
Vent System Length
3.  Tighten hose clamp with Phillips screwdriver. 
4.  Make sure the vent is secured to exhaust hood with  
a 4" (102 mm) clamp.
5.  Move dryer into final position. Do not crush or kink vent. 
Make sure dryer is level.
12" min.
(305 mm)
Vent Collar