Monogram ZEU36RSJSS Installation Instruction

Page of 16
4
Installation Instructions
PREPARING THE OPENING
 (CONT)
5
  Make sure the wall coverings, countertop and 
cabinets around the cooktop can withstand 
heat (up to 200°F) generated by cooktop.
4
 
CUTOUT DIMENSIONS OF THE 
COUNTERTOP
To insure accuracy, it is best to make a template 
when cutting the opening in the counter.
2-1/2" Min.  
from front edge 
of cutout and 
front edge of 
countertop
19-1/8" to 19-1/4” 
width of cut
33-7/8" to 
34” length 
of cut
1-3/4" Min. Between 
cutout and the wall 
behind the cooktop
Wall covering, 
cabinets and 
countertop must 
withstand heat up 
to 200°F. 
6
  For Americans with Disabilities Act (ADA) 
Forward Approach Installation Only:
NOTE: The enclosure must be made of wood 
material. Also, an access panel is required for the 
junction box, hold-down brackets, and service.
For models with 
no drop box, 
allow 5” minimum 
depth between the 
countertop and an 
enclosure (JP3536).
For electronic 
touch and backlit 
knob models, allow 
6-1/2” minimum 
depth between the 
countertop and an 
enclosure. 
(All other models)
6 1/2”
Drop 
box
5”
2
 
APPROXIMATE COOKTOP 
DIMENSIONS
20-3/8"  
Depth on Monogram ZEU36  
is 20-7/8” @ center.
33-3/4"
Cooktop
36"  
(36-1/8" SS)
18-7/8"
3-1/4" Front  
4-3/16" Rear  
at the conduit 
location (JP3536) 
6" Rear (All other 
models)
3
 
VERTICAL CLEARANCE
Allow 5” minimum  
vertical clearance  
from the cooktop  
bottom (or 8-1/4”  
minimum depth from 
the countertop) to any  
combustible surfaces,  
such as a cabinet  
drawer.
DRAWER
5" 
8-1/4"