Cabinet Dimension Requirements
Dimensions for 27” Wall-Mounted Units
Single Oven 27”
For single ovens installed in a wall cabinet, the junction 
box may be located above or beneath the unit within 
reach of the power cable.
Flush installation requires two side cleats to be attached 
inside the cabinet frame, recessed from the front.
It is good practice, when oven is installed at the end of a 
cabinet run, adjacent to a perpendicular wall or cabinet 
door, to allow at least 1/4” space between the side of the 
oven and the wall/door.
For oven support, install 2x4’s extending front to back flush 
with the bottom and the side of the opening. The supporting 
base must be well secured to the floor/cabinet and level.
Note:
The conduit box can be installed above or to the right of the 
unit, within range of the power conduit. 
The cabinet cavity must be plumb and the base must be flat  
and level and capable of supporting a weight of at least 193 
lbs (87 kg). 
Double Oven 27”
For single ovens installed in a wall cabinet, the junction 
box may be located above or beneath the unit within 
reach of the power cable.
Flush installation requires two side cleats to be attached 
inside the cabinet frame, recessed from the front.
It is good practice, when oven is installed at the end of a 
cabinet run, adjacent to a perpendicular wall or cabinet 
door, to allow at least 1/4” space between the side of the 
oven and the wall/door.
For oven support, install 2x4’s extending front to back flush 
with the bottom and the side of the opening. The supporting 
base must be well secured to the floor/cabinet and level.
Note: 
The conduit box must be located above the unit to facilitate 
connecting and servicing.