solver!
PROBLEM
POSSIBLE CAUSE
FAN DOES NOT
• A fuse may be blown or a circuit breaker tripped. Replace fuse or 
OPERATE WHEN
reset circuit breaker.
THE SWITCH IS ON
FAN FAILS TO
• Fan blade striking the hood shell.
CIRCULATE AIR
• Excessively soiled filter should be checked and corrected before 
using the hood again.
FAN OPERATES BUT 
• Check to be sure the filter is clean. If replacing the filter does not 
MOVES AIR SLOWER
correct the problem, call for service.
THAN NORMAL
FAN KEEPS GOING 
• The motor is probably overheating and turning itself off. This can 
OFF AND ON
be harmful to the motor. Check to be sure the filter is clean. If off 
and on cycling continues, call for service.
CLEAN FILTER LIGHT 
• The filters have been in place for 30 hours of “on” time. Remove the 
IS ON OR BLINKING
filters, clean if necessary and replace them. Make sure they are 
correctly seated in the filter channels. Adjust as necessary until the 
red signal light stops blinking. See the Metal grease filter/
Clean filter light 
section.