3
30"
(762mm)
21"
(533mm)
4" (102mm)
Chassis height
1/4" (6mm) Min.
to combustibles
below chassis
27 1/2"
(699mm)
19 7/8" (505mm)
3 1/8"
(79mm)
7 1/2" (191mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2 1/4"
(57mm) Min.
Vertical
combustible
surface
Rear
wall
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for the
SGM304
36"
(914mm)
21"
(533mm)
19 7/8"
(505mm)
33 3/4"
(857mm)
4" (102mm)
Chassis height
3 1/8"
(79mm)
1/4" (6mm) Min.
to combustibles
below chassis
7 1/2" (191mm) Min.
to combustible
side wall above
the cooktop
(both sides)
2 1/4"
(57mm) Min.
Vertical
combustible
surface
Rear
wall
2"
(51mm) Min.
25" (635mm)
Minimum
Cutout Dimensions for the
SGM364 & SGM365
(SGM365 model shown)
21"
(533mm)
4" (102mm)
46"
(1168mm)
44 1/2"
(1130mm)
19 7/8" (505mm)
3 1/8"
(79mm)
1/4" (6mm) Min.
to combustibles
below chassis
7 1/2" (191mm) Min.
to combustible
side wall above
the cooktop
(both sides)
Vertical
combustible
surface
Rear
wall
2 1/4"
(57mm) Min.
2"
(51mm) Min.
25" (635mm)
Minimum
6 1/2"
(165mm)
30 1/2"
(775mm)
14"
(356mm)
Cutout Dimensions for the
SGM466 and SGM464GG
(SGM464GG model shown)
NOTES:
1. The only downdraft approved
for use with the SGM464GG
is the Dacor ERV/PRV. Dacor
recommends a 54 inch wide
hood with a minimum 1100
CFM blower.
2. The SGM464GG cooktop is
approved for 2” (51mm) min.
clearance to combustibles
below the chassis.
3. For the SGM464GG, a
noncombustible material is to
be installed on the underside
of a cabinet located above the
grill section in accordance
with local codes, or in the
absence of local codes, with
the National Fuel Gas Code,
ANSI Z223.1/NFPA 54.
Gas and Electrical Supply
Requirements
WARNINGS:
1. If the gas or electric service
provided does not meet
the product specifications,
do not proceed with the
installation. Call the selling
dealer, the gas supplier, or a
licensed electrical or plumbing
contractor.
2. The grounding plug must not,
under any circumstances, be
cut or removed.
3. This appliance must be
installed by a licensed
plumber or gas fitter
when installed within
the Commonwealth of
Massachusetts.
NOTES:
1. All gas cooktops have the gas
and electrical located in the
back right corner as you face
the front of the appliance.
2. Each cooktop ships with a
factory regulator in the box.
All 30, 36, and the SGM464
models utilize 1/2” regulators.
The SGM 466 uses a 3/4”
regulator, which is approved
for connection to a 1/2” house
gas supply.