Viking RVER33015BBK Installation Instruction

Page of 28
19
1
2
Measure the four corners in cutout area to 
verify if flooring is level. 
For uneven or sloped floors, level unit with 
metal shims only, as the adjustment required may
exceed the thread available in the leg.
3
3/8”
3/
8”
 
(0.95 cm)
(0.
95
 cm
)
3/8”
 
(0.95 cm)
4
Move unit into opening.
Leveling/Adjustments/Alignment
5
Check that unit is level side to 
side and front to back. Side trim of the high corner
must be 3/8” (0.95 cm) above countertop.
If leveling is required, move unit out of opening.
6
1
2
1
Lift unit and prop on wood blocks.