GE GTX42GASJWW Specification Sheet

Page of 3
GTX42GASJ 
GE
® 
Series 6.2 cu. ft. capacity Aluminized alloy drum  
gas dryer with HE Sensor Dry
Specification Created 7/15
For answers to your Monogram,
® 
GE Profile
 or GE
®
 appliance questions, visit our 
website at geappliances.com or call GE Answer Center
®
 service, 800.626.2000.
22 1/2"
26 3/4"
4"
1 3/4"
3 1/4"
4 1/4"
37 1/2"
44"
27"
5"
Power Cord 4 1/2"
11 3/4"
Side View
Rear View
EXHAUST OPTION: When viewed from the 
front of the unit, exhaust 3-way via rear, left 
and bottom. Dryer is shipped exhausted to 
the rear. Alternate exhausting knockouts are 
supplied.
GAS:  An individual, properly-grounded branch 
circuit, with a three-prong grounding-type 
receptacle, protected by a 15 or 20 amp circuit 
breaker or a time-delay fuse is required.
GAS DRYER ELECTRIC RATING:  
120V, 60Hz, 6A
GAS (BTU/HR): 22,000. Factory-equipped for 
natural gas. Tested for LP gas. LP gas supply 
requires a conversion kit. Check installation 
instructions for correct kit and have a qualified 
gas technician install a conversion kit. See dryer 
ducting information for proper installation.
NOTE: Dryer wall outlet must be located within 
36" of service cord entry and accessible when 
dryer is mounted in position.
INSTALLATION INFORMATION:  
For complete information, see installation 
instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION: 
-  If your dryer is approved for installation in an alcove or closet, it will be stated on a label  
 
on the dryer back.
- The dryer MUST be exhausted to the outside.
-  Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 
0" either side; 3" front and rear
- Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
-  Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of 
open area equally distributed. If this closet contains both a washer and a dryer, doors must contain 
a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
-  The dryer MUST be exhausted to the outdoors.
-  The installation must conform with the local codes, or in the absence of local codes, with the 
National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
-  Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
DRYER EXHAUSTING INFORMATION :  
Use metal duct only, vertical and horizontal ducting.