GE GTX42GASJWW Fiche Technique
GTX42GASJ
GE
®
Series 6.2 cu. ft. capacity Aluminized alloy drum
gas dryer with HE Sensor Dry
Specification Created 7/15
For answers to your Monogram,
®
GE Profile
™
or GE
®
appliance questions, visit our
website at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
22 1/2"
26 3/4"
4"
1 3/4"
3 1/4"
4 1/4"
37 1/2"
44"
27"
5"
Power Cord 4 1/2"
11 3/4"
Side View
Rear View
EXHAUST OPTION: When viewed from the
front of the unit, exhaust 3-way via rear, left
and bottom. Dryer is shipped exhausted to
and bottom. Dryer is shipped exhausted to
the rear. Alternate exhausting knockouts are
supplied.
GAS: An individual, properly-grounded branch
supplied.
GAS: An individual, properly-grounded branch
circuit, with a three-prong grounding-type
receptacle, protected by a 15 or 20 amp circuit
receptacle, protected by a 15 or 20 amp circuit
breaker or a time-delay fuse is required.
GAS DRYER ELECTRIC RATING:
GAS DRYER ELECTRIC RATING:
120V, 60Hz, 6A
GAS (BTU/HR): 22,000. Factory-equipped for
GAS (BTU/HR): 22,000. Factory-equipped for
natural gas. Tested for LP gas. LP gas supply
requires a conversion kit. Check installation
requires a conversion kit. Check installation
instructions for correct kit and have a qualified
gas technician install a conversion kit. See dryer
gas technician install a conversion kit. See dryer
ducting information for proper installation.
NOTE: Dryer wall outlet must be located within
NOTE: Dryer wall outlet must be located within
36" of service cord entry and accessible when
dryer is mounted in position.
INSTALLATION INFORMATION:
dryer is mounted in position.
INSTALLATION INFORMATION:
For complete information, see installation
instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a label
on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 3" front and rear
- Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of
- Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of
open area equally distributed. If this closet contains both a washer and a dryer, doors must contain
a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes, with the
National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
DRYER EXHAUSTING INFORMATION :
- Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
DRYER EXHAUSTING INFORMATION :
Use metal duct only, vertical and horizontal ducting.