Wine Guardian Through-the-Wall 2200 BTUH Air-cooled Wine Cooling Unit Installation Instruction

Page of 39
32
System Does Not Start-up
Thermostat Light is Off
Possible Cause
Solution
        Voltage switch not in correct position
Check position
No power to outlet
Check circuit breaker and wiring
Unit not plugged in
Plug in the system
LCDI tripped                                                   Reset
Thermostat Light is On
Possible Cause
Solution
Thermostat is not set up properly
Check thermostat set up in the guide.
System is Operating and Blows Evaporator Air, but  the
Supply Air is Not Colder Than the Return Air from the Cellar
Possible Cause
Solution
Thermostat not set up properly
Check thermostat setup in the manufacture’s
thermostat guide
Compressor not operating
              High pressure switch open (button up) (see
            below)
Condenser airflow is blocked
Remove blockage
             Clean coil (if needed)
Head Pressure (HP)  switch is open
Reset HP switch 
 
See reset  instructions on
page  27