Intel Xeon X3440 BX80605X3440 User Manual

Product codes
BX80605X3440
Page of 106
Introduction
10
Thermal/Mechanical Specifications and Design Guidelines
1.2
Definition of Terms
Table 1-2.
Terms and Descriptions (Sheet 1 of 2)
Term
Description
Bypass
Bypass is the area between a passive heatsink and any object that can act to form a 
duct. For this example, it can be expressed as a dimension away from the outside 
dimension of the fins to the nearest surface.
CTE
Coefficient of Thermal Expansion. The relative rate a material expands during a thermal 
event.
DTS
Digital Thermal Sensor reports a relative die temperature as an offset from TCC 
activation temperature.
FSC
Fan Speed Control
IHS
Integrated Heat Spreader: a component of the processor package used to enhance the 
thermal performance of the package. Component thermal solutions interface with the 
processor at the IHS surface.
ILM
Independent Loading Mechanism provides the force needed to seat the 1156-LGA land 
package onto the socket contacts.
PCH
Platform Controller Hub. The PCH is connected to the processor via the Direct Media 
Interface (DMI) and Intel
®
 Flexible Display Interface (Intel
®
 FDI).
LGA1156 socket
The processor mates with the system board through this surface mount, 1156-land 
socket.
PECI
The Platform Environment Control Interface (PECI) is a one-wire interface that provides 
a communication channel between Intel processor and chipset components to external 
monitoring devices.
Ψ
CA
Case-to-ambient thermal characterization parameter (psi). A measure of thermal 
solution performance using total package power. Defined as (T
CASE
 – T
LA
) / Total 
Package Power. The heat source should always be specified for Ψ measurements.
Ψ
CS
Case-to-sink thermal characterization parameter. A measure of thermal interface 
material performance using total package power. Defined as (T
CASE
 – T
S
) / Total Package 
Power.
Ψ
SA
Sink-to-ambient thermal characterization parameter. A measure of heatsink thermal 
performance using total package power. Defined as (T
S
 – T
LA
) / Total Package Power.
T
CASE 
or
 
T
C
The case temperature of the processor, measured at the geometric center of the topside 
of the TTV IHS.
T
CASE
_
MAX
The maximum case temperature as specified in a component specification. 
TCC
Thermal Control Circuit: Thermal monitor uses the TCC to reduce the die temperature by 
using clock modulation and/or operating frequency and input voltage adjustment when 
the die temperature is very near its operating limits.
T
CONTROL
T
CONTROL
 is a static value that is below the TCC activation temperature and used as a 
trigger point for fan speed control. When DTS > T
CONTROL
, the processor must comply 
with the TTV thermal profile. 
TDP
Thermal Design Power: Thermal solution should be designed to dissipate this target 
power level. TDP is not the maximum power that the processor can dissipate.
Thermal Monitor
A power reduction feature designed to decrease temperature after the processor has 
reached its maximum operating temperature.
Thermal Profile
Line that defines case temperature specification of the TTV at a given power level.
TIM
Thermal Interface Material: The thermally conductive compound between the heatsink 
and the processor case. This material fills the air gaps and voids, and enhances the 
transfer of the heat from the processor case to the heatsink.