For SIA CP-01 Compliance 
CC# Exit Tone
 can be set to Yes or No
CC# Arm Now Warning 
Default: 
No  
Selection: 
Yes or No 
Yes 
This keypad activates a tone and 
displays PLEASE CLOSE NOW. 
No 
This keypad does not activate the 
tone or display PLEASE CLOSE 
NOW. 
Determines whether this keypad sounds a tone and 
displays the PLEASE CLOSE NOW warning on the 
keypad when a Closing Window activates, indicating 
the area automatically arms soon. 
CC# Close Door 
Default: 
No 
Selection: 
Yes or No 
Yes 
This keypad sounds a tone and 
displays CLOSE DOOR #. 
No 
This keypad does not sound the 
tone or activate the display. 
Determines whether this keypad sounds an audible 
tone and displays the CLOSE DOOR # warning on 
the keypad. This occurs when the door is physically 
held open past the shunt time and the extend time 
has a value greater than zero for the door assigned 
to this area in CC# Assign Door. Refer to the 
D9210B Program Entry Guide (P/N: 32207). 
 
CC# Passcode Follows Scope 
Default: 
Yes  
Selection:  Yes or No 
Yes 
Master Arming allows a user to 
change the armed state of the areas 
within the scope of this keypad. If the 
areas in the scope are already at the 
intended armed state, they remain in 
that state. 
  If the area to which this keypad is 
assigned is armed, entering a 
valid passcode disarms this area 
and all other areas assigned to 
the scope of this keypad.  
  If the area to which this keypad is 
assigned is disarmed, entering a 
valid passcode arms this area 
and all other areas assigned to 
the scope of this keypad. 
No 
Restricts the scope of the keypad to 
the Area programmed in CC# Area 
Assign
 for the purpose of executing 
L## Passcode Arm and  
L## Passcode Disarm only. 
Use this program to determine if this keypad follows 
CC# Scope or if it only arms or disarms the area to 
which it is assigned. The user must have authority 
enabled in L## Passcode Arm and L## Passcode 
Disarm
. This feature does not affect the Function List 
arming and disarming commands. 
 
Tokens and cards disarm according to 
this prompt. If this prompt is No, tokens 
disarm only the Area to which the CC# is 
assigned. The user must have disarming 
rights for tokens and cards programmed 
at the Disarm Level. The user does not 
need disarming and arming authority for 
the keypad. 
 
 
You can use this prompt for a group of 
account-wide keypads that only arm the 
area to which they are assigned, even if 
the user has a passcode with arming 
authority rights in all areas.