10.4. Power Connection
The DART 300 requires a nominal 12.0 V DC regulated power source capable of supplying 1 amp
maximum. Refer to Section 14.1 below for more details.
maximum. Refer to Section 14.1 below for more details.
Sierra Wireless provides a connector with bare wire leads in each package (part number 6000067).
The connector in the DART 300 unit is a Molex Micro-Fit
™
3.0 male housing (PN 43020-0200).
The mating part is a Molex Micro-Fit 3.0 female housing (PN 43025-0200); using two female
terminal pins (PN 43030-0001) crimped to 20-24 AWG wire. Note that the connector housing and
the pins inside are separate parts from Molex and will require assembly by the user.
terminal pins (PN 43030-0001) crimped to 20-24 AWG wire. Note that the connector housing and
the pins inside are separate parts from Molex and will require assembly by the user.
Red Wire
(Positive)
Black Wire
(Negative)
Figure 10-4: Power Connector.
The connector is rated for 30 connect / disconnect cycles.
Connect the power cord to the power source using a 1 Amp fuse.