Motorola DSP56012 User Manual

Page of 270
Digital Audio Transmitter
DAX Programming Considerations
 
MOTOROLA
DSP56012 User’s Manual 
8-15
8.6.4
DAX Operation During Stop
The DAX operation cannot continue when the DSP is in the Stop state since no DSP 
clocks are active. While the DSP is in the Stop state, the DAX will remain in the 
individual reset state and the status flags are initialized as described for resets. No 
DAX control bits are affected. It is recommended that the DAX be disabled, by 
clearing the XEN bit in the XCTR, before the DSP enters the Stop state.