White Rodgers 1F80ST-0471 User Manual

Page of 8
4
INSTALLER/CONFIGURATION MENU 
Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the 
next menu item. Press 
 or 
 to change a menu item. Shaded items are not available on 1F86.
1.  Select Reversing Valve Output (SS/HP switch must 
be set at HP, omitted if SS/HP switch is SS Position) 
– The O/B option is factory set at "O" position. This will 
accommodate the majority of heat pump applications, 
which require the changeover relay to be energized in 
FRIO. If the thermostat you are replacing or the heat pump 
being installed with this thermostat requires a "B" terminal, 
to energize the changeover relay in CALOR, the O/B 
option should be set at "B" position.
2.  Program Options 1F80 only – This control can be 
confi gured for 5/2 day or 5/1/1 day programming or non-
programming mode. The default setting is P2, indicating 
5/2 day programming. The programs per week can be 
toggled to P3 or P0 by pressing the 
 or 
 keys. A 
selection of 0 Days for non-programmable will eliminate 
the need for EMR, and that step in the menu will be 
skipped.
3. Select Frio Ahorro (Cool Savings™) and value 
– Selects the Frio Ahorro feature On or OFF. If selected 
On, press MENU to select the amount of adjustment 
for the feature in Frio mode with 1 (1°) being the least 
amount of adjustment and 6 (6°) being the most amount 
of adjustment. Default value is 3 (3°). In normal operation 
"Ahorro" will appear under "Vent"
 
Cool Savings is an optional energy saving feature that 
can reduce your cooling costs. It is based on the principal 
that lower indoor humidity makes a slightly higher 
temperature feel more comfortable. Frio Ahorro operates 
during periods of high demand which normally occur 
on the hottest summer days when the cooling system 
may run for hours to reach the thermostat setting. Long 
cooling run times also lower the indoor humidity. Frio 
Ahorro
 very slowly adjusts the setpoint temperature to 
make the setpoint closer to the displayed temperature, to 
a maximum number of degrees selected. Adjusting the 
setpoint temperature over a long cooling run time allows 
the system to reach your set temperature and turn off. 
The room temperature will actually be higher than the 
thermostat displays, but the reduction in humidity will allow 
comfort at the slightly higher temperature. When Frio 
Ahorro
 is making adjustments, "Save" will show next to 
the setpoint temperature and the room temperature may 
vary within the adjustment range selected. 
 
If this feature is selected OFF, no change will occur when 
the cooling system is continually running during periods of 
high demand.
INSTALLER/CONFIGURATION MENU
MENU 
REF
HP
SS
PRESS 
BUTTON
DISPLAYED 
(FACTORY DEFAULT)
Press 
 or 
 to 
select from listed options
COMMENTS
1
1
MENU
On (Frio O)
Calor b On
Reversing Valve Output (SS/HP switch must 
be in the Heat Pump HP position)
2
2
1
MENU
P (2)
P 3, P 0
Selectable Programs Per Week 
(For programmable thermostat only)
3
3
2
MENU
Frio Ahorra CE 
(OFF)
Frio Ahorra CE On
Select Frio Ahorra (Cool Savings) on or off
MENU
Frio Ahorra (3)
6, 5, 4, 2, 1
Selects Frio Ahorra value 1 (low) to 6 (high)
4
4
3
MENU
E (On)
E OFF
Selects Energy Management Recovery (EMR)
on or off
5
4
MENU
CR Calor
(ME)
AL, bA
Adjustable Anticipation (Calor) (only when
SS/HP switch is at the SS position)
6
5
MENU
CR Frio
(AL)
bA
Adjustable Anticipation (Frio) (only when
SS/HP switch is at the SS position)
7
5
MENU
CR Bomba de Calor
(AL)
bA
Adjustable Anticipation (Bomba de Calor) 
(only when SS/HP switch is at the HP position)
8
6
6
MENU
Cd (OFF)
Cd On
Compressor Lockout Time
9
7
7
MENU
Auto Calor
Frio Off
Calor Frio Off,
Calor Off with Vent icon, 
Calor Off without Vent
icon, Frio Off,
Auto Off
System Mode Confi guration
with Automatic Changeover
10
8
8
MENU
L (On)
L OFF
Selects Display Light on or off
11
9
9
MENU
0
1 AL, 2 AL, 3 AL, 4 
AL,
1 bA, 2 bA, 3 bA, 4 bA
Adjustable Ambient Temperature Display
12
10
10
MENU
F
C
Selects Fahrenheit/Celsius Temperature 
Display
13
11
11
MENU
Cambiar Filtro (OFF)
Cambiar Filtro On
Selects Filter Change-out Indicator
MENU
Cambiar Filtro 200 h
25 h to 1975 h in
25-hour increment
When on, selects time in 25 hour increments
14
12
12
Arrancar
Returns to Normal Operation