Connecting a Pelconet Transmitter To The CM6800 ASCII Port
Refer to Figure 51. This configuration lets an operator view and control cameras with a PC using a web
browser. (The operator’s PC is not shown on the diagram.) All settings are done in the CM6800 manager
program or through a CM6800 menu. Note the following:
Port 2 defaults to ASCII and RS-232.
Ports 7 and 8 can be set to ASCII and RS-232 by using the CM6800 manager program (refer to
Figure 51) or by using a CM6800 menu (refer to Figure 52).
Pelco recommends using Port 2.
TRANSP
ARENT
 DA
T
A
 POR
T
TO
 NETWORK (LAN / 
WA
N
)
CONTROL
TERMINAL
ALARM I/O
PELCONET
TRANSMITTER
SPECTRA
 COAXITRON
®
 PROT
OCOL
VIDEO IN
2-RX
3-TX
5-GND
PELCONET
 CM6800-48X8
TRANSP
ARENT
 DA
T
A
 POR
T
 
COM2
2 RXD...................................................
8 TXD
3 TXD...................................................
1 RXD
5 GND..................................................
5 GND
CONNECT
 PELCONET
 T
O
 6800 VIA
 RS-232 POR
T
6800 MA
TRIX COM 2
POR
T
 SETTINGS:
BAUD RA
TE 
9600
DA
T
A
 BITS
8
PA
RITY
ODD
ST
OP
 BIT
1
USING INTERNET
 EXPLORER,
SET
 TRANSP
ARENT
 DA
T
A
POR
T
 SETTINGS:
BAUD RA
TE 
9600
DA
T
A
 BITS
8
PA
RITY
ODD
ST
OP
 BIT
1
CM6800-48X8
PELCONET CM6800 ASCII PORT SETUP
00669
Figure 51.
 Using PelcoNet with CM6800 to Provide Remote Control