Sony HDCU-950 User Manual

Page of 82
3-1 (E)
HDCU-950 IMM
Section 3
Service Overview
3-1. Cleaning of Connector/Cable
Before connecting the unit to the camera, it is recommend-
ed to clean the following optical contact portions.
. CAMERA connector of the unit
. CCU connector of the camera side
. Optical/electrical cable
Follow the procedures below for cleaning.
Tools Required
. Alignment sleeve remover HC-001
(for female connector)
Sony P/N : J-6480-010-A
n
Insert the shorter nose end when removing/installing the
alignment sleeve.
Grasp not the shock absorber portion of the remover but
the handle in use.
. Cotton swabs (commercially available)
n
Use a cotton swab whose diameter is about 4 mm.
If a cotton swab whose diameter exceeds 5 mm is used,
the cotton swab cannot be inserted into the end of the
connector and the tip of the optical contact cannot be
cleaned.
Use the shorter nose end.
Shock absorber
Handle
Cleaning
Male connector
Clean the tip of the white optical contacts by a cotton swab
moistened with alcohol.
Female connector
The optical contacts for female connector are in an unex-
posed state. In cleaning, it is necessary to be exposed by
removing the alignment sleeve in advance. Proceed as
follows.
1.
Insert the alignment sleeve remover into the alignment
sleeve in the straight line and turn it clockwise.
Optical contacts (white)
Alignment sleeve
Alignment sleeve remover