3com S8520X-28S 0235A370 User Manual
Product codes
0235A370
1-14
Table 1-16
Fan tray specifications
Model
Specification
Description
Fan number
z
Two 70 × 70 × 25.4 mm (2.76 × 2.76 × 1 in.) fans
z
Four 40 × 40 × 28 mm (1.57 × 1.57 × 1.1 in.) fans
Fan speed
z
70 × 70 × 25.4 mm (2.76 × 2.76 × 1 in.) fans: 4700 R.P.M
z
40 × 40 × 28 mm (1.57 × 1.57 × 1.1 in.) fans: 9500 R.P.M
Max airflow
150 cubic feet per minute (CFM)
Input voltage
12 V
LSW1FAN
Total power
consumption
consumption
15 W
Fan number
1
Fan speed
5000 R.P.M
Max airflow
41.65 CFM
Input voltage
12 V
LSW1BFAN
Total power
consumption
consumption
24 W
For the detailed characteristics and specifications of the two models of fan trays, see H3C LSW1FAN &
LSW1BFAN Installation Manual
.
Cooling System Introduction
The ventilations on the two sides of the chassis, the hot swappable fan trays, and the hot swappable
power modules of the S5820X series form an effective cooling system, ensuring that the heat generated
by the device and power modules can be exhausted in time, and thus enhance device stability. When
installing an S5820X series, place the device according to the ventilation design of the installation
environment.
power modules of the S5820X series form an effective cooling system, ensuring that the heat generated
by the device and power modules can be exhausted in time, and thus enhance device stability. When
installing an S5820X series, place the device according to the ventilation design of the installation
environment.
The heat dissipation process of the S5820X-28S is as shown in
. Air enters from the
ventilations on the two sides of the chassis, carries the heat generated by the switch and power
modules, and then goes out from the air outlets of the turbo fan and power fan. The switch and the
power module each has its independent air channel for heat dissipation. Keep the air channels with
good ventilation when the switch is operating.
modules, and then goes out from the air outlets of the turbo fan and power fan. The switch and the
power module each has its independent air channel for heat dissipation. Keep the air channels with
good ventilation when the switch is operating.