ACR Electronics 1933 User Manual

Page of 16
Y1-03-0232D 
Wiring to the searchlight 
The  RCL-300A  searchlight  is  supplied  with  a  15-foot  integral  wire 
harness. If you must lengthen the wire harness, use heavy duty wire to 
minimize the voltage drop. This is especially important for the WHITE 12 
AWG lamp power, BLACK 12 AWG lamp ground, ORANGE power wire 
and BLUE ground wires. 
 
Following the wiring scheme above and 
Appendix  C.
 
use  the  supplied  butt 
connectors  to  connect  the  Master 
Controller to the searchlight. 
 
Wiring the Point Pad™ 
The  RG-59  coax  cable  is  supplied 
without  the  “F”  connectors  attached  for 
ease  of  routing.  After  the  Coax  cable 
has been routed, strip the insulation and 
crimp  the  “F”  connectors  in  place. 
Screw the “F” connectors to the Master 
Controller and the Point Pad™. 
 
Wiring to the power supply  
The  power  source  must  be  a  fused  12 
VDC,  30-amp  supply  or  a  24  VDC,  15-
amp  supply.  Following  the  wiring  scheme  in  Table  1,  use  the  supplied 
butt  connectors  to  connect  the  Master  Controller  to  the  power  source. 
Refer  to Table  2  for  proper  wire  size  for  connection  of  the  input  power 
lines. 
 
NOTE: As per the wiring scheme, the ORANGE wire is connected to the 
positive  terminal  and  the  BLUE  wire  is  connected  to  the  negative 
terminal of the power source.  
 
CAUTION:    HID  light  systems,  when  first  turned  on,  have  a  high 
inrush current requirement of 25 amps. If  you  activate the light  and the 
lamps  flicker  on  and  off  repeatedly,  check  the  voltage  being  supplied. 
This condition can be experienced with voltage input of less than 11.5V. 
 
 
Functions of the URC-300 
The  URC-300  Master  Controller  is  designed  to  perform  up  to  six 
different  duties  on  searchlights,  winches  and  other  electrical  devices. 
The  Master  Controller  provides  optimum  voltage  to  ensure  brightest 
performance  and  long  lamp  life,  regardless  of  boat  system  voltage 
fluctuations.  The  Master  Controller  is  compatible  with  devices  requiring 
12 VDC through 24 VDC operation.  
 
Figure 5