Furuno FSV-35 User Manual

Page of 66
2.  WIRING
2-16
2.9
Input Voltage and Fuses
The transceiver unit is shipped from the factory with its input voltage set for 230 VAC 
and a 10 A fuse inserted in F601 and F602. For other voltages, change toggle switch 
positions and fuses shown below. 
Input voltage and toggle switch
Fuses
Change the fuse in F601 and F602 according to input voltage, referring to the table 
below.
How to mark the input voltage label
After setting toggle switches and changing 
the fuses, mark the label on the inside of the 
cover with the voltage that applies. In the ex-
ample shown below, 100 V is checked; 20 A 
fuses are used.
Input voltage
S603
S604
S605
Default 
setting
100 VAC
L
L
L
-
110 VAC
H
L
L
-
115 VAC
H
H
L
-
220 VAC
H
L
H
-
230 VAC
H
H
H
Default
Input Voltage 
(TB-B101)
F601
F602
Default 
setting
100 VAC
20A
20A
-
110 VAC
-
115 VAC
-
220 VAC
10A
10A
-
230 VAC
Default
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage to the 
equipment or cause fire.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FUSE             FUSE
F601             F602
INPUT
(TB-B101)
FUSE
F601     F602
100V
110V        20A       20A
115V
220V
230V
10A       10A