Topcon GPT-2006 User Manual

Page of 168
7-6
   7 DATA COLLECTION
Example for setting the direction angle:
The following is to memorize the data of the backsight after setting the backsight point from point 
number. 
Operating procedure
Operation
Display
1
Press the [F2](BACKSIGHT) key from the data 
collect menu 1/2.
The previous data is shown.
[F2]
2
Press the [F4] (BS) key. *1)
[F4]
3
Press the [F1](INPUT) key and enter PT#. *2)
[F1]
Enter PT#
[F3]
4
Press the [F3](YES) key. 
Enter PCODE,R.HT in the same way. *3),4)
[F3]
5
Press the [F3](MEAS) key.
[F3]
6
Collimate back sight point.
Select  one of the measuring mode and press the 
soft key.
EXAMPLE : [F2](Slope Distance) key.
Horizontal circle is set to calculated direction 
angle. Measuring starts.
Measuring result is memorized and the display 
returns to the data collect menu 1/2.
Collimate 
BS 
[F2]
*1) Pressing each time the [F3] key, the input method changes as Coordinate value, Angle, Coordinate 
point name alternatively.
*2) Refer to Chapter 2.6 “How to Enter Alphanumeric characters”.
*3) PCODE can be input by inputting a register number linked with PCODE Library.
To show the list of PCODE library, press the [F2](SRCH) key.
*4) Data collect sequence can be set to [EDIT
If point is not found in internal memory " PT# DOES NOT EXIST" is displayed.
  
BS#   
PCODE :
R.HT  :   0.000 m
INPUT 0SET MEAS BS
  
BACKSIGHT
 PT#:
INPUT LIST NE/AZ ENT
  
 M:    0.000m
 E:    0.000m
 Z:    0.000m
>OK?      [YES] [NO]
  
BS#   
PT-22
PCODE :
R.HT  :   0.000 m
INPUT 0SET MEAS BS
  
BS#   
PT-22
PCODE :
R.HT  :   0.000 m
*VH   SD  NEZ  NP/P
  
 V :   90°00'00"
 HR:    0°00'00"
 SD*[n]     <<< m
> Measuring...
  
DATA COLLECT    1/2
 F1:OCC.PT# INPUT
 F2:BACKSIGHT
 F3:FS/SS        P