Topcon GPT-2006 User Manual

Page of 168
   7 DATA COLLECTION
7-7
7.2
Operational Procedure of “DATA COLLECT”
Operating procedure
Operation
Display
1
Press the [F3](FS/SS) key from the data collect
menu 1/2.
The previous data is shown.
[F3]
2
Press the [F1](INPUT) key and enter PT#.
Press the [F4](ENT) key. *1)
[F1]
Enter PT#
[F4]
3
Enter PCODE, R.HT in the same way. *2),3)
4
Press the [F3](MEAS) key. 
5
Collimate the target point.
[F1]
Enter 
PCODE
[F4]
[F1]
EnterR.HT
[F4]
[F3]
Collimate
6
Press one of the [F1] to [F3] key. *4)
Example: [F2](SD) key.
Measuring starts.
The measuring data is memorized and the display 
changes to the next point. *5)
PT# is automatically incremented.
[F2]
7
Enter the next point data and collimate the next 
point.
Collimate
8
Press [F4](ALL) key.
Measuring starts in the same measuring mode of 
the previous point.
Data is recorded.
Continue the measuring in the same way.
To finish the mode , press [ESC] key. 
[F4]
  
DATA COLLECT     1/2
 F1:OCC.PT# INPUT
 F2:BACKSIGHT
 F3:FS/SS         P
  
PT#   
PCODE :
R.HT  :   0.000 m
INPUT SRCH MEAS ALL
  
PT#   =PT-01
PCODE :
R.HT  :   0.000 m
1234 5678 90.– [ENT]
  
PT#   :PT-01
PCODE 
R.HT  :   0.000 m
INPUT SRCH MEAS ALL
PT#   
PT-01
PCODE :TOPCON
R.HT  :   1.200 m
INPUT SRCH MEAS ALL  
VH  *SD   NEZ    P1
    
 V :  90°10'20" 
 HR: 120°30'40"
 SD*[n]        < m
> Measuring... 
    < complete >
  
PT#   
PT-02
PCODE :TOPCON
R.HT  :   1.200 m
INPUT SRCH MEAS ALL
 V :  90°10'20" 
 HR: 120°30'40"
 SD*[n]        < m
> Measuring... 
    < complete >
  
PT#   
PT-03
PCODE :TOPCON
R.HT  :   1.200 m
INPUT SRCH MEAS ALL