3M 965AMS User Manual

Page of 204
 
199
3M™ Dynatel™ Advanced Modular System 965AMS 
Specifications
Specifications
Electrical Specifications
Functions
Range 
Resolution
Accuracy
Voltage (DC) 
0 to 99.9 V 
100 to 300 V 
0.1 V 
1 V
1% ± 0.5 V 
3%
Voltage (AC) 
Meter resistance 
100 k or 1 m 
0 to 99.9 V 
100 to 250 V 
0.1 V 
1 V
1% ± 0.5 V 
3% 
Current
 
Shunt resistance
0 to 59.9 mA 
60 to 110 mA 
430 Ω 
0.1 mA 
0.1 mA 
1% ± 0.3 mA 
2% 
Resistance 
With CO voltage 
0 to 9999 Ω 
0 to 9999 Ω 
10 k to 99.9 kΩ 
100 k to 999 kΩ 
1 M to 9.9 MΩ 
10 M to 99 MΩ 
100 M to 990 MΩ 
1 Ω 
1 Ω 
0.1 kΩ 
1 kΩ 
10 kΩ 
0.1 MΩ 
1 MΩ 
1% ± 5 Ω
1% ± 50 Ω
1% 
3% 
3% 
5% 
10% 
Opens (no noise) 
0 to 3,000 ft  
(0 to 1,000 m) 
3,000 to 10,000 ft  
(1 km to 3 km) 
10,000 to 50,000 ft 
(3 km to 15 km) 
50,000 to 100,000 ft (15 
km to 30 km) 
1 ft (1 m) 
 
1 ft (1 m) 
 
10 ft (10 m) 
 
100 ft (100 m) 
1% ± 3 ft (1 m)  
3% 
 
5% 
 
10% 
RFL 
Fault range 
Resistance to 
Fault (no noise) 
0 to 20 MΩ 
0 to 99.99 Ω 
100 to 999.9 Ω 
1 k to 3 kΩ 
— 
RTS 0.01 Ω
RTS 0.1 Ω
RTS 1.0 Ω
— 
0.1% of RTS ± 0.01 Ω
1
0.2% of RTS ± 0.01 Ω
1
1.0% of RTS ± 0.01 Ω
1
Wet section test 
Loop resistance Resistive 
balance 
0 to 7 kΩ 
0 to 3.5 kΩ 


5% 
Loop resistance 
0 to 99.9 Ω 
100 to 999.9 Ω 
1000 to 7000 Ω 
0.01 Ω 
0.1 Ω 
1 Ω 
0.1% ± 0.01 Ω 
0.2% ± 0.01 Ω 
1.0% ± 0.01 Ω 
Resistance difference 
0 to 99.99 Ω 
0.01 Ω 
1% of loop resistance 
± 0.01 Ω 
Note:  
1
All resistance to fault measurement accuracies have an added factor of (2x10
-8
) R
f
 ohms (R
=fault resistance in ohms)