Self-Test Board
 
3M™ Dynatel™ Advanced Modular System 965AMS
Self-Test Board>Check RFL Performance 
1.  Connect the test leads as shown. Press the 
 key on the 
965AMS tester. 
3 965AMS
2.  Press the 
Setup
 key, enter 70°F (21°C) for temperature.
3.  Press the 
OK
 key to accept. 
4.  Select Separate Pair hookup, then continue. You should see 
the following readings for different wire gauges (US and 
Canada).
AWG
DTS
DTF
DSTF
Min
Max
Min
Max
Min
Max
19
11910 
(3630)
12290 
(3747)
1170 
(357)
1230 
(375)
10730 
(3271)
11070 
(3375)
22
5986 
(1825)
6171 
(1881)
592 
(180)
613 
(187)
5393 
(1644)
5559 
(1695)
24
3755 
(1145)
3871 
(1180)
371 
(109)
385 
(117)
3383 
(1031)
3488 
(1063)
25
2970 
(905)
3063 
(934)
293 
(89)
305 
(93)
2676 
(816)
2759 
(841)
26
2347 
(716)
2420 
(738)
232 
(71)
240 
(73)
2114 
(645)
2180 
(665)
28
1479 
(451)
1526 
(465)
146 
(44)
152 
(46)
1332 
(406)
1375 
(419)
Ohms
99.3
102.5
9.8
10.2
89.5
92.3