Hoshizaki KM-260BAH User Manual

Page of 81
40 
 
PROBLEM POSSIBLE 
CAUSE 
REMEDY 
[1] (Continued) 
l) Control Board 
1. Defective. 
1. See “II. 3. [d] CONTROL 
BOARD CHECK 
PROCEDURE”. 
1. Connector 
disconnected. 
1. Reconnect. 
2. Leads opened or 
defective switch. 
2. Check and replace. 
a) Float Switch 
3. Float does not move 
freely. 
3. Clean or replace. 
[2] Water 
continues to 
be supplied, 
and the 
icemaker will 
not start. 
b) Control Board 
1. Defective. 
1. Replace. 
1. WASH position. 
1. Move to ICE position. 
a) Control Switch 
2. Bad contacts. 
2. Check and replace. 
1. Dirty air filter or 
condenser. 
1. Clean. 
2. Ambient temperature 
too warm. 
2. Reduce ambient 
temperature. 
3. Refrigerant 
overcharged. 
3. Recharge. 
4. Fan not operating. 
4. See chart 2 - [6]. 
5. Condenser water 
temperature too warm 
(water-cooled model). 
5. Check and get 
recommended 
temperature. 
b) High Pressure 
Control 
6. Refrigerant line or 
components plugged. 
6. Clean and replace drier. 
1. Bad contacts. 
1. Check for continuity and 
replace. 
2. Voltage too low. 
2. Increase voltage. 
c) Overload 
Protector 
3. Refrigerant overcharged 
or undercharged. 
3. Recharge. 
1. Bad contacts. 
1. Check and replace. 
d) Starter 
2. Coil winding opened. 
2. Replace. 
e) Start Capacitor 
1. Defective. 
1. Replace. 
1. Bad contacts. 
1. Check for continuity and 
replace. 
f) Power Relay 
2. Coil winding opened. 
2. Replace. 
1. Wiring to compressor. 
1. Check for loose 
connection or open, and 
replace. 
2. Defective. 
2. Replace. 
g) Compressor 
3. Protector tripped. 
3. Reduce temperature and 
verify cause. 
h) Control Board 
1. Defective. 
1. See “II. 3. [d] CONTROL 
BOARD CHECK 
PROCEDURE”. 
i) Condenser, Air 
Filter 
1. Clogged with dirt and 
dust. 
1. Clean and unclog. 
1. Set too high. 
1. Adjust lower. 
[3] Compressor 
will not start or 
operates 
intermittently. 
j) Water regulator 
(water-cooled 
model) 
2. Clogged or defective. 
2. Clean or replace.