41 
 
PROBLEM POSSIBLE 
CAUSE 
REMEDY 
a) Inlet Water Valve 
1. Diaphragm does not 
close. 
1. Check for water leaks 
with icemaker off. 
Replace if necessary. 
[4] Water 
continues to 
be supplied in 
freeze cycle. 
b) Control Board 
1. Defective. 
1. See “II. 3. [d] CONTROL 
BOARD CHECK 
PROCEDURE”. 
a) Water Supply Line
1. Water pressure too low 
and water level in water 
tank too low. 
1. Check and get 
recommended pressure. 
b) Inlet Water Valve 
1. Dirty mesh filter or 
orifice and water level in 
water tank too low. 
1. Clean. 
1. Water leaks. 
1. Check connections for 
water leaks, and replace. 
c) Water System 
2. Clogged. 
2. Clean. 
1. Motor winding opened. 
1. Replace. 
2. Bearing worn out. 
2. Replace. 
3. Wiring to pump motor. 
3. Check for loose 
connection or open, and 
replace. 
4. Defective capacitor. 
4. Replace. 
d) Pump Motor 
5. Defective or bound 
impeller. 
5. Replace and clean. 
[5] No water 
comes from 
Spray Tubes. 
Water Pump 
will not start, or 
freeze cycle 
time is too 
short. 
e) Control Board 
1. Defective. 
1. See “II. 3. [d] CONTROL 
BOARD CHECK 
PROCEDURE”. 
1. Motor winding opened. 
1. Replace. 
2. Bearing worn out. 
2. Replace. 
3. Wiring to fan motor. 
3. Check for loose 
connection or open, and 
replace. 
a) Fan Motor 
4. Fan blade bound 
(locked fan motor). 
4. Check and replace. 
[6] Fan Motor will 
not start, or is 
not operating. 
b) Control Board 
1. Defective. 
1. See “II. 3. [d] CONTROL 
BOARD CHECK 
PROCEDURE”. 
1. Undercharged. 
1. Check for leaks and 
recharge. 
a) Refrigerant 
2. Air or moisture trapped.
2. Replace drier, and 
recharge. 
b) Compressor 
1. Defective. 
1. Replace. 
[7] All 
components 
run but no ice 
is produced. 
c) Hot Gas Solenoid 
Valve 
1. Continues to open in 
freeze cycle. 
1. Check and replace.