Dacor DMT2420 w/AMTK Leaflet

Page of 1
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
CI.24
microwave/renaissance wall Oven/
warming Oven
COmBINATION INSTALLATIONS
CUTOUT DImENSIONS
DmT2420 SHOwN
CUTOUT DImENSIONS
DCm24 SHOwN
Wall Oven 
Models
“B” Cutout Width
Single 27”
25 1/2” (648mm)
Single 30”
28 1/2” (724mm)
Single 36”
34 1/2” (876mm)
Microwave
Model No.
“A” Cutout Width
DMT2420 w/AMTK Series Trim Kit
24 3/8” (619mm)
DCM24 w/ACTK27  Trim Kit
25 1/4” (641mm)
DCM24 w/ACTK30  Trim Kit
28 1/4” (718mm)
DCM24 w/ACTK36  Trim Kit
25” (635mm)
Warming 
Oven 
Models
“C” Cutout Width
27”
25 1/2” (648mm)
30”
28 1/2” (724mm)
 
NOTE:
1.   3/4” (19mm) support platform (flush with cutout).
2. 
See individual appliance Planning Guide pages to 
determine overlays.
3. 
Spacing between appliances and drawers/doors 
shown is minimum required to allow for ventilation 
and prevent scrapping.  Additional space may need 
to be added for appearance.
1/1
9 1/8”
(232mm)
27 5/8”
(702mm)
16 3/4”
(425mm)
1 7/8”
(48mm)
Min.
1 1/2”
(38mm)
Min.
“B” 
“C”
“A”
120 Vac
Microwave
Receptacle
240 Vac
Wall Oven
Junction Box
1
7/8” (22mm) Min.
3/4” (19mm)
Min.
58 1/2”
Min.
(1486mm)
Overall 
Stacked 
Height
120 Vac Warming 
Oven Receptacle
9 1/8"
(232mm)
27 5/8"
(702mm)
1 5/8"
(41mm)
Min.
1 1/2" 
(38mm)
Min.
“B”
“A”
120 Vac
Microwave
Receptacle
240 Vac
Wall Oven
Junction Box
1
1
1
3/4" 
(19mm) Min.
3/4" (19mm)
Min.
60 1/2"
Min.
(1536mm)
Overall 
Stacked 
Height
“C”
120 Vac Warming 
Oven Receptacle
19 1/8"
(486mm)
Revised
05/29/08