Dacor DMT2420 w/AMTK プリント
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
CI.24
microwave/renaissance wall Oven/
warming Oven
COmBINATION INSTALLATIONS
CUTOUT DImENSIONS
DmT2420 SHOwN
CUTOUT DImENSIONS
DCm24 SHOwN
Wall Oven
Models
“B” Cutout Width
Single 27”
25 1/2” (648mm)
Single 30”
28 1/2” (724mm)
Single 36”
34 1/2” (876mm)
Microwave
Model No.
“A” Cutout Width
DMT2420 w/AMTK Series Trim Kit
24 3/8” (619mm)
DCM24 w/ACTK27 Trim Kit
25 1/4” (641mm)
DCM24 w/ACTK30 Trim Kit
28 1/4” (718mm)
DCM24 w/ACTK36 Trim Kit
25” (635mm)
Warming
Oven
Models
“C” Cutout Width
27”
25 1/2” (648mm)
30”
28 1/2” (724mm)
NOTE:
1. 3/4” (19mm) support platform (flush with cutout).
2.
2.
See individual appliance Planning Guide pages to
determine overlays.
determine overlays.
3.
Spacing between appliances and drawers/doors
shown is minimum required to allow for ventilation
and prevent scrapping. Additional space may need
to be added for appearance.
shown is minimum required to allow for ventilation
and prevent scrapping. Additional space may need
to be added for appearance.
1/1
9 1/8”
(232mm)
27 5/8”
(702mm)
16 3/4”
(425mm)
1 7/8”
(48mm)
Min.
1 1/2”
(38mm)
Min.
“B”
“C”
“A”
120 Vac
Microwave
Receptacle
240 Vac
Wall Oven
Junction Box
1
1
1
7/8” (22mm) Min.
3/4” (19mm)
Min.
58 1/2”
Min.
(1486mm)
Overall
Stacked
Height
120 Vac Warming
Oven Receptacle
9 1/8"
(232mm)
27 5/8"
(702mm)
1 5/8"
(41mm)
Min.
1 1/2"
(38mm)
Min.
“B”
“A”
120 Vac
Microwave
Receptacle
240 Vac
Wall Oven
Junction Box
1
1
1
3/4"
(19mm) Min.
3/4" (19mm)
Min.
60 1/2"
Min.
(1536mm)
Overall
Stacked
Height
“C”
120 Vac Warming
Oven Receptacle
19 1/8"
(486mm)
Revised
05/29/08
05/29/08
All tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated