– 13 –
TIME
Time is displayed in “hours & minutes”. When the unit 
is fi rst powered on, the time display shows “--:--”.  To 
increase time, turn knob to the right, and to decrease 
time, turn knob to the left.  When the knob stops, the 
displayed time countdown then begins. 
When the time counts down to "00:00", the display will 
fl ash and the operator will be alerted with a buzzer and 
lights (based on parameter settings). To add time, turn 
the knob to the right to the desired additional time. The 
buzzer stops when additional time is added. To mute 
the buzzer function, turn the knob to the left with the 
door shut.  The display lights will still fl ash.  Opening 
the door stops the time and the buzzer. Shutting the 
door will reset the time function to the last time setting.  
When the door is opened during an active countdown time, the time pauses and restarts when the door 
is shut. 
At the end of a time cycle “00:00” fl ashes. If no adjustment of the time knob is made and “00:00” is still 
displayed when the door is shut, the last time setting is automatically recalled and the time countdown 
starts again.
To manually return to a no time setting, turn the timer knob to the left until --:-- is displayed. The time 
function does not control or affect the heating or humidity functions.  
Setting time works the same when the door is either open or closed.  Time does not count down when 
the door is open. 
HUMIDITY
The humidity set point has an automatic setting based 
on temperature selection. The operator can increase 
or decrease the humidity setting manually by turning 
the knob more than 1 indent to the left to decrease or 
more than 1 indent to the right to increase. Turning only 
1 indent displays actual oven cavity humidity.  
Recall of the last humidity setting also occurs when the 
temperature is switched off and then back on.  Default 
settings are used unless a manual humidity setting 
adjustment is made.
NOTE:  When checking actual humidity the display may 
show " - " while the sensor is initializing.