AMX RE-DM4 User Manual

Page of 90
AMX RADIA Lighting Programming
44
 RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules
SEND_COMMANDs
The Radia Eclipse firmware supports the SEND_COMMANDs listed in the table below. The number of 
SEND_COMMANDs is expected to grow as we transition away from using the SEND_STRING method of 
controlling Radia dimmers. 
Note that most SEND_COMMANDs do not have responses. With those that do, they respond with a 
COMMAND, not a string.
Conventions used in this protocol section of the document include:
Ramp Preset Up (NEW)
This function ramps up the specified or currently active (last recalled) preset until the ramp is stopped or the all 
dimmers in the preset reach 100%. 
If <preset> is not specified, then the last recalled preset is ramped. 
The ramp rate for this function is the default ramp time as established by the 'RT' command. 

Only dimmers that are assigned a level greater than 0 in the preset are ramped. 

Dimmers with a level of 0 and Undefined dimmers are not affected by the PU command.
SEND_COMMAND Protocol Conventions
Symbol Function
Values
<m>
Value for Dimmer Level (in %)
0-100
<n>
Value for Dimmer Number
1-6 or A for all. Can include a range of dimmers or ranges of dim-
mers unless noted otherwise. For example:
• “1-3” indicates dimmers 1 through 3 inclusive.
• “1-3&5-6” indicates dimmers 1 through 3 and 5 through 6, 
inclusive.
• “A” indicates ALL dimmers.
<s>
Value for preset number
1-128
<t>
Time value for fade (in seconds) 0-255
Use the 'PS' command to stop preset ramping. This command allows the 
programmer to specify which preset to stop.
Ramp Preset Up
Command:
PU<preset>
Response:
None
Examples:
SEND_COMMAND Radia,'PU'
Ramp last preset up
SEND_COMMAND Radia,'PS'
Stop ramping.
SEND_COMMAND Radia,'PU52'
Ramp preset 52 up
SEND_COMMAND Radia,'PS52'
Stop ramping preset 52