Set Curve
This function sets the specified dimmer(s) to follow the specified curve.
Curve Status (NEW)
This function returns the curves assigned to each dimmer. The response will be an incoming COMMAND to 
the master.
Set Low End (NEW)
This function sets the minimum on percentage for the specified dimmer (i.e. a level of 0 will still be off). 
For example, if the low end is set to 10, then any request for a level between 1-10 will result in the output level 
being 10; a request for 0 will be 0; a request for a level between 11-100 will result in the outputting of that 
level. 
This function is used to prevent certain loads from dimming below the product's ability.
Low End Status (NEW)
This function returns the low end settings assigned to each dimmer. The response will be an incoming 
COMMAND to the master.
Reboot (NEW)
This function reboots the dimmer and initializes it to its power-up state. The device will go off-line and then 
return on-line with the master controller.
Set Curve
Command:
SC<dimmer>C<curve>
Response:
None
Examples:
SEND_COMMAND Radia,'SC1C1'
Set dimmer 1 to curve 1
SEND_COMMAND Radia,'SC1-4CN'
Set dimmers 1-4 to curve N
SEND_COMMAND Radia,"SCAC3'
Set all dimmers to curve 3
Curve Status
Command:
?C
Response:
?C-<curve1>,<curve2>,<curve3>,<curve4>,<curve5>,<curve6>
Example:
SEND_COMMAND Radia,'?C'
Request current curve settings
Response: 'C-1,1,1,1,N,N'
Set Low End
Command:
LE<dimmer>L<percent>
Response:
None
Example:
SEND_COMMAND Radia,'LE2L20'
Set minimum level of dimmer 2 to 20%
Low End Status
Command:
?LE
Response:
LE-<percent1>,<percent 2>,<percent 3>,<percent 4>,<percent 5>,<percent 6>
Example:
SEND_COMMAND Radia,'?LE'
Request current low end settings
Response: 'LE- 000, 005, 000, 000, 005, 000'
Reboot
Command:
RESET
Response:
None
Example:
SEND_COMMAND Radia,'RESET'
Reboot dimmer