Sony 8000SF User Manual

Page of 591
238
Multi Program 2
   
Cha
For details, see “Cross-Point Settings (Xpt Assign Menu)” in Chapter 16 
(Volume 2).
Enabling DME wipe operations for sub
By factory default, DME wipe operations are inhibited for sub background. To 
enable them, in the Engineering Setup >Switcher >Config menu, set [DME 
Wipe Sub Enable] to On.
This enables DME wipe operations for sub background.
This setting applies to the whole control panel (all M/E banks and PGM/PST 
bank).
Note
If a DME wipe for sub is recalled in a snapshot or keyframe, the image will not 
be handled correctly.
Inhibiting utility 2 bus signal selection
In Multi Program 2 mode, you can inhibit other uses of the utility 2 bus signal 
in order to use the signal as the background for sub.
This setting applies to the whole control panel (all M/E banks and PGM/PST 
bank).
In the Engineering Setup >Panel >Config >MP2 Main/Sub Assign menu, set 
[Util2 Inhibit] to On.
This inhibits operations of selecting from the background B row while holding 
down the [UTIL] button in the cross-point control block.
Including Multi Program 2 data in recall operations of keyframes 
and snapshots
In the Engineering Setup >Switcher >Config menu, set [Recall M/E Config] to 
On.
When a keyframe or snapshot is stored or recalled, the following data is 
included.
M/E Config, PGM Config, M/E Output Assign, and Key PVW Config
This setting applies to the whole control panel (all M/E banks and PGM/PST 
bank).
Note
M/E Config data is saved, even when this setting is Off.