Cabletron Systems 2M46 User Manual

Page of 120
Chapter 2: LM Security Screens for 2E43-51/2E43-51R Devices
2-8
Local Management Supplement
INTERFACE # (Selectable)
Used to select the front panel interface connector (ENET 1 to ENET 4) to 
which the port security settings will be applied. 
2.3.1
Setting the Port Level Security
To set the security for each repeater port on a connector, proceed as 
follows:
1.
Use the arrow keys to highlight the INTERFACE # field.
2.
Use the SPACE bar to step to the appropriate interface connector 
number (ENET 1 to ENET 4). 
3.
Press ENTER to display the ports on the chosen interface connector.
4.
Use the arrow keys to highlight the Security State field for the 
interface connector.
5.
Use the SPACE bar to step to the appropriate security level 
(NonSecure, LockOnNext, or LockedOnAddr).
6.
If the security level chosen causes the DisablePort and SendTrap 
fields to display under Action On Intruder, use the arrow keys to 
highlight the DisablePort field. If the security level chosen does not 
cause the fields to display under Action On Intruder, proceed to 
.
7.
To change the DisablePort setting to NoDisablePort, press the 
SPACE bar to toggle the setting.
8.
Use the arrow keys to highlight the SendTrap field.
9.
To change the setting to NoTrap, press the SPACE bar to toggle the 
setting.
10.
If the security state selected is LockedOnAddr, use the arrow keys to 
highlight the Address field for the port. Otherwise go to 
.
11.
Enter the MAC address, using the numerical keys. It is not necessary 
to separate the numbers with dashes when entering the address.
12.
 through 
once.