DELL N3000 User Manual

Page of 1460
874
Configuring Connectivity Fault Management
Configuring MEP Information
Beginning in Privileged Exec mode, use the following commands to configure 
the mode and view related settings.
CLI Command
Description
configure
Enter global configuration mode.
interface 
interface
Enter Interface Config mode for the specified 
interface, where 
interface
 is replaced by 
gigabitethernet 
unit/slot/port
, or tengigabitethernet 
unit/slot/port
ethernet cfm mep enable level 
level
 vlan 
vlan-id 
mpid 
mep-id 
Define the port as a maintenance endpoint (MEP) 
and associate it with an SVLAN in a domain. When 
the MEP is enabled, it will generate CCM messages.
ethernet cfm mep level 
level
 
direction {up | down} mpid 
mep-id 
vlan 
vlan-id 
Enable a MEP at the specified level and direction.
ethernet cfm mep active
Set the administrative state of the MEP to active.
ethernet cfm mip level 
level
 
Create a MIP at the specified level on the interface.
exit
Exit to privileged Exec Mode
show ethernet cfm 
maintenance–points
Add the keywords local domainlocal interface
local levelremote domain, or remote level to show 
information on local or remote endpoints.
show ethernet cfm statistics
Display statistics per MEP.