The Rear Panel – At a Glance 
Series N5700 User’s Guide 
13 
J2 Sense Connector 
1 – Remote sense (+) 
2 – Local sense (+) 
3 – Not used 
4 – Local sense (–) 
5 – Remote sense (–)
 
 
The factory-shipped configuration is shown in the figure. 
 
SW1 Setup Switch 
The factory-shipped setting is Down for all switches. 
 
1 – Output voltage, voltage 
      programming
 
Down: The output voltage is programmed by the front panel. 
Up:      The output voltage is programmed by the external voltage signal. 
2 – Output current, voltage 
      programming
 
Down: The output current is programmed by the front panel. 
Up:      The output current is programmed by the external voltage signal. 
3 – Programming range  
      (voltage/resistance) 
 
Down: The remote programming range is: 0 – 5V / 0 – 5KΩ. 
Up:      The remote programming range is: 0 – 10V / 0 – 10KΩ. 
4 – Voltage and Current  
      monitoring range
 
Down: The remote monitoring range is: 0 – 5V. 
Up:      The remote programming range is: 0 – 10V. 
5 – Shut-Off Logic Select 
Down: OUT OFF = Low (0 – 0.6V) or short;  OUT ON = High (2V – 15V) or open. 
Up:      OUT OFF = High (2V – 15V) or open;  OUT ON = Low (0 – 0.6V) or short. 
6 – Not Used  
 
7 – Output voltage, resistive 
      programming
 
Down: The output voltage is programmed by the front panel. 
Up:      The output voltage is programmed by the external resistor. 
8 – Output current, resistive 
      programming
 
Down: The output current is programmed by the front panel. 
Up:      The output current is programmed by the external resistor. 
9 – Enable/Disable control 
Down: The J1 Enable+/Enable– pins are not active. 
Up:      The J1 Enable+/Enable– pins are active. 
1
2
3
4
5
6 7
8
9