User ManualTable of Contents1 Quick Reference7The Agilent N5700 DC Power Supplies – At a Glance8Output Features8System Features8Programmable Functions9Model Ratings9The Front Panel - At a Glance10The Rear Panel – At a Glance12J2 Sense Connector13SW1 Setup Switch13J1 Analog Programming Connector14SCPI Programming Commands – At a Glance.15Subsystem Commands.15Common Commands162 Installation17General Information18Models18Options18Accessories18Items Supplied18Inspecting the Unit19Installing the Unit19Safety Considerations19Environment19Airflow19Rack Installation20Cleaning20Connecting the Line Cord21Input Connections for 750W units21Input Connections for 1500W units21Connecting the Load23Wire Size23Load Connections for 6V to 60V Models24Load Connections for 80V to 600V Models25Output Voltage Sensing26Local Sensing27Remote Sensing27Load Considerations28Multiple Loads28Output Noise and Impedance Effects29Inductive Loads29Grounding the Output30Parallel Connections30Setting up the Master Unit31Setting up the Slave Units31Setting the Over-Voltage Protection32Setting the Over-Current Protection32Series Connections32J1 Connector Connections343 Operating the Power Supply Locally35Turn-On Check-Out36Before Check-Out36Constant Voltage Check36OVP Check36UVL Check37Constant Current Check37OCP Check37Normal Operation38Constant Voltage Mode38Constant Current Mode38CV/CC Mode Crossover39CV/CC Signal39Protection Functions39Over-Voltage Protection39Under-Voltage Limit40Over-Current Protection40Over-Temperature Protection41Power-Fail Protection41Front Panel Lock-Out41Output On/Off Control42OUT ON button42Output Shut-Off Terminals42Enable/Disable Terminals43Power Supply OK Signal43Safe-Start and Auto-Restart43Daisy-Chained Output Shut-down44Analog Programming of Output Voltage and Current44Analog Programming Control Terminals45Voltage Programming of Output Voltage and Current45Resistance Programming of Output Voltage and Current46External Monitoring of Output Voltage and Current474 Operating the Power supply Remotely49Configuring the Interface50GPIB Interface50USB Interface51LAN Interface52Using the Setup Utility57Tips for the using the LAN interface58SCPI Commands – an Introduction59Syntax59Multiple Commands in a Message59Commands from Different Subsystems60Message Unit60Queries61Common Commands61Command Terminators61Parameter Types62Device Clear635 Language Reference65Calibration Commands66CALibrate:CURRent[:LEVel] <NRf>66CALibrate:DATA <NRf>66CALibrate:DATE “<date>” CALibrate:DATE?66CALibrate:LEVel P1|P266CALibrate:PASSword <NRf>66CALibrate:STATe <Bool> [,<NRf>] CALibrate:STATe?67CALibrate:VOLTage[:LEVel] <NRf>67Measure Commands67MEASure[:SCALar]:CURRent[:DC]? MEASure[:SCALar]:VOLTage[:DC]?67Output Commands68OUTPut[:STATe] <Bool> OUTPut[:STATe]?68OUTPut:PON:STATe RST|AUTO OUTPut:PON:STATe?68OUTPut:PROTection:CLEar68Source Commands69[SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf+> [SOURce:]CURRent[:LEVel][:IMMediate][:AMPLitude]? [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude] <NRf+> [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPLitude]?69[SOURce:]CURRent:PROTection:STATe <Bool> [SOURce:]CURRent:PROTection:STATe?69[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf+> [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]? [SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] <NRf+> [SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]?69[SOURce:]VOLTage:LIMit:LOW <NRf+> [SOURce:]VOLTage:LIMit:LOW?70[SOURce:]VOLTage:PROTection:LEVel <NRf+> [SOURce:]VOLTage:PROTection:LEVel?70Status Commands71STATus:PRESet72STATus:OPERation[:EVENt]?72STATus:OPERation:CONDition?72STATus:OPERation:ENABle <NRf> STATus:OPERation:ENABle?72STATus:OPERation:NTR <NRf> STATus:OPERation:PTR <NRf> STATus:OPERation:NTR? STATus:OPERation:PTR?73STATus:QUEStionable[:EVENt]?73STATus:QUEStionable:CONDition?73STATus:QUEStionable:ENABle <NRf> STATus:QUEStionable:ENABle?74STATus:QUEStionable:NTR <NRf> STATus:QUEStionable:PTR <NRf> STATus:QUEStionable:NTR? STATus:QUEStionable:PTR?74*CLS74*ESE *ESE?75*ESR?75*OPC *OPC?75*SRE *SRE?76*STB?76*WAI76System Commands77SYSTem:COMMunicate:RLSTate LOCal|REMote|RWLock SYSTem:COMMunicate:RLSTate?77SYSTem:ERRor?77SYSTem:VERSion?77*IDN?77*OPT?78*RCL <NR1>78*RST78*SAV <NR1>78*TST?78Trigger Commands79ABORt79INITiate[:IMMediate][:TRANsient]79INITiate:CONTinuous[:TRANsient] <Bool> INITiate:CONTinuous[:TRANsient]?79TRIGger[:TRANsient][:IMMediate]79TRIGger:SOURce BUS TRIGger:SOURce?79*TRG796 Programming Examples81Output Programming Example82Trigger Programming Example83A Specifications85Performance Specifications86Supplemental Characteristics87Outline Diagram89B Verification and Calibration91Verification92Equipment Required92Measurement Techniques93Constant Voltage Tests94Constant Current Tests97Test Record Form – Agilent N5741A and N5761A99Test Record Form – Agilent N5742A and N5762A100Test Record Form – Agilent N5743A and N5763A101Test Record Form – Agilent N5744A and N5764A102Test Record Form – Agilent N5745A and N5765A103Test Record Form – Agilent N5746A and N5766A104Test Record Form – Agilent N5747A and N5767A105Test Record Form – Agilent N5748A and N5768A106Test Record Form – Agilent N5749A and N5769A107Test Record Form – Agilent N5750A and N5770A108Test Record Form – Agilent N5751A and N5771A109Test Record Form – Agilent N5752A and N5772A110Calibration111Calibration Procedure111C Service113Types of Service Available114Repackaging for Shipment114Operating Checklist114Turn-on check out procedure114Trouble-shooting guide114Error Messages116Displaying the SCPI error queue116Error List116D Compatibility121Differences – In General122Compatibility Command Summary123Index125Size: 2.25 MBPages: 128Language: EnglishOpen manual