Agilent Technologies N5700 User Manual

Page of 128
Analog Programming of Output Voltage and Current 
Series N5700 User’s Guide 
47 
The analog control circuits let you set the output voltage and current 
limit up to 5% over the model-rated maximum value. The power 
supply will operate within the extended range, however it is not 
recommended to operate the power supply over its voltage and 
current rating, and performance in this region is not guaranteed. 
 
SW1 switch 3 
Voltage Programming  
(J1 pin 9) 
Current programming 
(J1 pin 10) 
Down (default) 
0 – 5 kΩ 
0 – 5 kΩ 
Up 
0 – 10 kΩ 
0 – 10 kΩ 
 
External Monitoring of Output Voltage and Current 
The J1 connector also provides analog signals for monitoring the 
output voltage and current. Selection of the voltage range between 0 
– 5 V or 0 – 10 V is made by SW1 setup switch 4. The monitoring 
signals represent 0 to 100% of the power supply output voltage and 
current rating. The monitor outputs have a 500 Ω series output 
resistance. Make sure that the sensing circuit has an input resistance 
greater than 500 kΩ or the accuracy will be reduced. 
 
SW1 switch 4 
Voltage 
range 
J1 signal  
connection
Signal function 
Down (default) 
0 – 5 V 
J1 pin 11 
Voltage Monitor 
 
 
J1 pin 24 
Current Monitor 
Up 
0 – 10 V 
J1 pin 11 
Voltage Monitor 
 
 
J1 pin 24 
Current Monitor 
J1 pin 12 is the signal common for J1 pins 11 and 24. 
1
14
13
25
10
9
23
22
CURRENT LIMIT
PROGRAMMING
OUTPUT VOLTAGE
PROGRAMMING
PROGRAMMING 
RESISTOR
PROGRAMMING 
RESISTOR
OPTIONAL SETS
LOWER LIMIT
OPTIONAL SETS
LOWER LIMIT
OPTIONAL SETS
UPPER LIMIT
OPTIONAL SETS
UPPER LIMIT
12
8