IBM 09-0572-000 User Manual

Page of 101
7-12
C
HAPTER
 7: T
ROUBLESHOOTING
Shared RAM Write/Read Test Failure
Make sure the shared RAM address does not conflict with the 
adapter ROM or another device.
Run the test three times with a delay of at least 30 seconds 
between each test. If the error persists, power down the PC 
and try once more. 
Timer Test Failure
The adapter’s timer is incorrect or the PC timer is malfunctioning.
Run the test three times with a delay of at least 30 seconds 
between each test. If the error persists, power down the PC 
and try once more. 
Open Adapter for Ring Operation Test Failure
Make sure a lobe cable is properly connected to the adapter 
and that the other end of the cable is connected to a DAU, 
MAU, or CAU.
Run the test three times with a delay of at least 30 seconds 
between each test. If the error persists, power down the PC 
and try once more. 
Ring Operations Test Failure
Run the Group 2 Adapter Wrap Test. If the test is successful, 
the error condition may be related to the ring itself.
Make sure a lobe cable is properly connected to a MAU.
Make sure the selected adapter speed matches the ring 
speed. 
Try another shared RAM address and size. 
Retry the operation after delaying at least 30 seconds.