 Chapter 43 Alarm Commands
IES-612-51A User’s Guide
285
The following example displays the port alarm thresholds for all ports. “ifindex” identifies the 
interface.
43.5  Alarm Port Set Command
Syntax:
  ras> alarm port set <all|enet1|enet2|port> <severity>
where
This command sets the alarm severity threshold for recording alarms on an individual port(s). 
The system reports an alarm on a port if the alarm has a severity equal to or higher than the 
port’s threshold.
The following example has the IES-612-51A only record critical alarms on DSL port 7.
43.6  Alarm Tablelist Command
Syntax:
  ras> alarm tablelist [<alarm>|all] [<severity>|all] 
[<fac>|all][<target>[,<target>]] [<condition>|all]
where
Figure 139   Alarm Port Show Command Example
ras> alarm port show
 no      ifindex       severity
-----   ----------    -----------
01       01          minor
02       02          minor
03       03          minor
04       04          minor
05       05          minor
==================================== SNIP =================================
    Press any key to continue, 'e' to exit, 'n' for nopause
<all|enet1|enet
2|port>
=
Ports on the IES-612-51A.
Figure 140   Alarm Port Set Command Example
ras> alarm port set 7 critical
<fac>
=
The log facility (
local1~local7
) that has the device log 
the syslog messages to different files in the syslog server. 
See your syslog program’s documentation for details.
<target>
=
snmp|syslog|all
 The type of alarm messages that the 
device is to send (SNMP, syslog or all).