43.8  Alarm History Show Command
Syntax:
  ras> alarm history show [<severity>|all] [<alarm>|all] [<condition>|all] 
[<sdate>|all] [<edate>|all] [for|rev] [detail]]
where
This command displays historic alarms by severity, alarm category, alarm condition and/or 
dates.
The following example displays the historic critical level alarms for all alarm categories, and 
all conditions.
43.9  Alarm History Clear Command
Syntax:
  ras> alarm history clear [<alarm>|all <condition>|all] <severity>
This command removes historic alarm entries by alarm category, alarm condition or severity.
The following example removes the historic minor level alarms for all alarm categories, and 
all conditions.
<sdate>
=
The start date, in 
yyyy/mm/dd
 format.
<edate>
=
The end date, in 
yyyy/mm/dd
 format.
[for|rev]
=
The displaying order. Use 
for
 to display in chronological 
order starting from the oldest alarm. Use 
rev
 to display in 
reverse chronological order starting from the most recent 
alarm. 
[detail]
=
Display in-depth alarm information.
Figure 142   Alarm History Show Command Example
ras> alarm history show major all all all all rev detail
    no alarm   condition            severity timestamp      source
------ ------  -------------------- -------- -------------- -------
     1 enet   -down                 major    01/01 00:00:12 enet 1
               * NTENET1:GbE interface is down
     2 enet   +down                 major    01/01 00:00:10 enet 1
               * NTENET1:GbE interface is down
Figure 143   Alarm History Clear Command Example
ras> alarm history clear minor