SVAT Electronics CLEARVU11 User Manual

Page of 74
SVAT ELECTRONICS
now you can see
CLEARVU11
17
From the setup menu, you can access various aspects of the system, including camera setup, schedule setup, network 
setup and password setup.
▲▼-   Press these buttons to change the highlighted item.
•  ENTER - Press this button to enter the setup of the highlighted option. For the details of each option, please   
 
refer to the corresponding sections.
•  ESC (MENU/ESC) -- Press this button to escape from Setup Menu display, and return to Menu display. 
PRE-CAMERA SETUP
In Setup Menu display, press 
▲▼ to change the highlighted 
option to Pre-Camera, and then 
press ENTER to call up the Pre-
Camera Setup display as shown.
Up to 4 cameras can be connected to the system. The Pre-Camera Setup allows the administrator to define some 
fundamental attributes for the installed cameras.
The general operations are as below:
▲▼◄► - Press these buttons to select the items.
•  Numeric (CH1-CH4) - Press these buttons to select the camera.
•  ESC (MENU/ESC) - Press this button to escape from this screen, and return to Setup Menu display. If the 
contents have been modified, a Save dialog will be shown to ask the user to save the changes, press ENTER 
to exit and save, ESC (MENU/ESC) to exit without saving.
Following is a brief description for each item and its specific operations:
•  REC Resolution – the record resolution for all the cameras in the system. For NTSC, it can be 720x480, 
720x240, or 360x240; for PAL, 720x576, 720x288, or 360x288. Press +/- buttons to select the resolution.
•  Watermark - press ENTER buttons to change the value. The watermark will permanently record time and 
date over the video clips. This is very important when logging video data, and using video as evidence. 
•  Installed – whether this camera is installed or not. Press ENTER or +/- to check/uncheck this item. The 
default setting is “” - checked. When the camera is checked saying it is installed you can adjust the 
settings of that camera in the Camera Settings menu. If it is not checked, no adjustments can be made. 
•  PTZ ID – the PTZ ID of this camera if it’s a PTZ camera. The PTZ ID has to be consistent with the setting of this 
camera. Please refer to the manual of the camera for the ID settings. Press +/- buttons to change the value 
(N/A or 0-255). The default setting is “N/A” – Not Available, which means that it’s not a PTZ camera.
MAIN MENU