SVAT Electronics CLEARVU11 User Manual

Page of 74
SVAT ELECTRONICS
now you can see
CLEARVU11
29
MAIN MENU
The following is a brief description of each item and its specific operations:
•  Size (GB) – the total HDD storage in GB (Giga-Byte) for Alarm Record and Normal Record respectively. This item 
is just for information. Please refer to the section on HDD format/clear for detailed information and setup.
•  Auto Overwrite – allows you to automatically overwrite the recorded video/audio from HDD#1 when the 
Alarm/Normal Record disk drive capacity is full. If Auto Overwrite is disabled and the Alarm/Normal Record disk 
drive capacity reaches the end, the system will not overwrite the recorded video/audio, and hence not record 
Alarm/Normal video/audio, until the user presses the Alarm Reset button. Press ENTER or +/- to check/
uncheck this item. The default setting is “” - checked.
•  HDD Full Action –Activates certain actions when Alarm/Normal Record disk drive capacity reaches the end of 
the last HDD. Press ENTER or +/- to check/uncheck this item. The default setting is “” - checked.
•  Duration – response duration to define how long (in seconds) the Alarm Out relay and the Buzzer will keep 
being triggered after the corresponding selection, Alarm Record or Normal Record, is full. Press +/- buttons to 
adjust the value (3-60 seconds, discrete).
•  Alarm Out – to define which Alarm Output will be triggered when the corresponding selection, Alarm Record 
or Normal Record, is full. Press +/- buttons to select none (N/A) or one of the Alarm Outputs (1-2).
•  Buzzer – to activate the internal Buzzer or not when the corresponding partition, Alarm Record or Normal 
Record, is full. Press ENTER or +/- to check/uncheck this item. The default setting is “” - checked.
•  Log – to log to event logs or not. Press ENTER or +/- to check/uncheck this item. The default setting is “” - 
checked.
•  E-mail – to send the event e-mail to a pre-determined email address or not. The e-mail will be sent to the 
predefined receivers when the event is triggered. Press ENTER or +/- to check/uncheck this item. The default 
setting is “–” - unchecked.
The general operations are as below:
▲▼◄►- Press these buttons to select the items.
•  MODE Format/Clear - Press this button to format/clear the HDDs as described in the next section.
•  ESC (MENU/ESC) - Press this button to escape from this screen, and return to Setup Menu display. If the Save 
dialog is shown, press ENTER to exit and save, ESC (MENU/ESC) to exit without saving.