RS-232/422/485  SETUP
In Setup Menu display, press 
▲▼ to change the highlighted 
option to RS-232/422/485, and 
then press ENTER to call up RS-
232/422/485 Setup as shown.
The RS-232/422/485 Setup allows the administrator to setup RS-232 control port, and RS422 or RS-485 control port. 
Please refer to the manuals for the connected devices - PTZ cameras – to set these items in RS-232/422/485 Setup.
Following is a brief description for each item and its specific operations:
•  Device Type – PTZ or N/A (Not Available). Press +/- buttons to change the type. Please note that PTZ can 
only be selected for either RS-232 or RS-485, but not both.
•  Model – PTZ model of the connected devices. The PTZ models supported include Pelco D protocol Dome, 
SamSung SCC-641P, etc. Press +/- buttons to change the supported model (or protocol).
•  Baud Rate – press +/- buttons to change the value. This is a specific value defined by your PTZ camera. Please 
consult your PTZ manual for the baud rate and protocol. 
•  Data Bit – press +/- buttons to change the value.
•  Stop Bit – press +/- buttons to change the value.
•  Parity – (Odd, Even, or None). Press +/- buttons to change the value.
•  DVR/Camera ID – for PTZ - the device ID for this digital video/audio recorder, and it must not conflict with the 
other devices connected in the same control port. Press +/- buttons to change the ID. Consult your PTZ manual 
for instructions on changing the PTZ ID. 
The general operations are as below:
▲▼◄►- Press these buttons to select the items.
•  MODE - Press this button to call up Optional RS-232 Setup screen if it’s built in the DVR. The operations for 
Optional RS-232 Setup are the same as RS-232/422/485 Setup.
•  ESC (MENU/ESC) - Press this button to escape from this screen, and return to Setup Menu display. If the Save 
dialog box is shown, press ENTER to exit and save, ESC (MENU/ESC) to exit without saving.
 